Showing 1-10 of 524 results

Browse for Ultrasonic Level Transmitter best prices at RankeDeal.com

  • Flowline DL10-01 EchoPod Ultrasonic Level Transmitter with Fob, 1" NPT

    The general purpose ultrasonic level transmitter provides continuous level measurement up to 49.2" (1.25m) with a 4-20 mA signal output, and is configured via our free WebCal software. This non-contact liquid level sensor is ideally suited for corrosive, sticky or dirty liquids, and is broadly selected for small day tank, skid, IBC, sump and process tank level applications. Range: 49.2" (1.25m). Accuracy: 0.125" (3mm). Resolution: 0.019" (0.5mm). Dead band: 2" (5cm). Beam width: 2" (5cm). Configuration: WebCal PC Windows USB 2.0 USB 2.0. Memory: Non-volatile. Supply voltage: 24 VDC (loop). Consumption: 0.5W. Loop resistance: 400O maximum. Signal output: 4-20 mA, two-wire. Signal invert: 4-20 mA or 20-4 mA. Signal fail-safe: 4 mA, 20 mA, 21 mA, 22 mA or hold last. Process temperature: F: 20 to 140 degree, C: -7 to 60 degree. Temperature comp.: Automatic. Ambient temperature: -31 to 140 degree F, -35 to 60 degree C. Pressure: MWP = 30 PSI (2 bar). Enclosure rating: Type 6P, encapsulated, corrosion resistant and submersible. Encloser material: Polycarbonate. Strain relief material: Santoprene. Trans. material: PVDF. Cable jacket material: Polyurethane. Cable type: 4-conductor, shielded. Cable length: 48" (1.2m). Process mount: 1" NPT. Mount gasket: Viton. Classification: general pur...

    • ASIN: B0061OXHOU
    • Brand: Flowline
    • ASIN: B0061OXHOU
    • Part No: DL10-01

  • Flowline DL24-01 Polycarbonate EchoPod Multi Function Ultrasonic Level Transmitter with Fob, 1" NPT, 9.8' Range

    The general purpose ultrasonic level transmitter provides continuous level measurement up to 9.8’ (3m) with a 4-20 mA signal output, and is configured via our free Webcal software. The level sensor has 4 programmable relays with selectable hysteresis and fail-safe logic. The embedded level controller can lower cost by replacing external control hardware. This non-contact liquid level sensor is ideally suited for corrosive, sticky or dirty liquids, and is widely selected for day tank, skid, IBC, sump and process tank level applications. Range: 9.8' (3m). Accuracy: +/- 0.2 percent of range. Resolution: 0.039" (1mm). Dead band: 4" (10cm). Beam width: 2" (5cm). Configuration: WebCal PC Windows USB 2.0. Memory: Non-volatile. Supply voltage: 24 VDC (loop). Consumption: 0.5W. Loop resist.: 400O maximum. Signal output: 4-20 mA, two-wire. Signal invert: 4-20 mA or 20-4 mA. Signal fail-safe: 4 mA, 20 mA, 21 mA,22 mA or hold last. Contact type: (4) SPST relays. Contact rating: 60 VA, 1A maximum. Contact fail-safe: Power loss: Hold last. Echo loss: Open, closeor hold last. Hysteresis: Selectable. Process temperature: F: 20 to 140 degree C: -7 to 60 degree. Temperature comp.: Automatic. Ambient temperature: F: -31 to 140 degree C: -35 to 60 degree. Pressure: MWP = 30 PSI (2 bar). Enclosure ...

    • ASIN: B0061OXNOO
    • Brand: Flowline
    • ASIN: B0061OXNOO
    • Part No: DL24-01

  • Flowline LU27-01 EchoSonic II Ultrasonic Level Transmitter with 9.8' Cable and Fob, 1" NPT

    Offered in a type 6P enclosure with cable interface, the general purpose ultrasonic level transmitter provides continuous level measurement up to 32.8' with a 4-20 milliampere signal output, and is configured via our free Webcal software. This non-contact liquid level sensor is ideally suited for corrosive, ultrapure, sticky or dirty liquids, and is broadly selected for bulk storage, day tank, lift station and process tank level applications. Submersible type 6P enclosure is ideal for sump and below grade installations. Short 4" or 8" dead band maximizes the measurable filling capacity of the tank. Measurement range: 4" to 9.8'. Accuracy: +/- 0.2 percent of range. Resolution: 0.019". Dead band: 4". Beam width: 2". Configuration: WebCal PC. Windows USB 2.0. Memory: Non-volatile. Supply voltage: 24 VDC (loop). Consumption: 0.5W. Loop resistance: 500 ohms at 24 VDC. Signal output: 4-20 milliampere two-wire. Signal invert: 4-20 or 20-4 milliampere. Signal fail-safe: 4, 20, 21, 22 milliampere or hold last. Process temprature: -4 degree to 140 degree F. Temprature compensation: automatic. Ambient temprature: -31 degree to 140 degree F. Pressure: MWP equal to 30 PSI. Enclosure rating: Type 6P, encapsulated, corrosion resistant and submersible. Enclosure material: polycarbonate. Transduc...

    • ASIN: B0061OZRL6
    • Brand: Flowline
    • ASIN: B0061OZRL6
    • Part No: LU27-01

  • Hanchen Ultrasonic Level Transmitter, Ultrasonic Water Level Meter Gauge 1~20M Liquid Level Flow Sensor, One Year Warranty (1m)

    Hanchen We provide ONE YEAR warranty for every our customer. Please note the Default Output is 4~20mA; Output RS485 or Modbus is optional.Please note the Default Input is DC 24V; Input DC12V is optional. If you need optional Output / Input / Extra Function【Object Position Tester】or 【Anticorrosive Probe】or 【High Temperature and Pressure】, please CHOOSE the one you want and place ANOTHER order. Thanks. Description It can be used in biogas pool depth measurement, Mixing tank depth level measurement, Water level measurement, Object position measurement, Well depth water level measurement in industrial process control, environmental protection, petroleum, chemical and other industries. Suitable for acid, alkali and salt, corrosion, high temperature and other environment. Technical Parameter Measuring range: 1m Blind zone: 0.25m~0.6m Accuracy: 0.3% (standard conditions) Resolution: ≤ 2mm (built-in temperature compensation) Pressure: normal atmospheric pressure Display: 4 digit LED display level or spatial distance Analog output(Default): 4~20mA ; Digital output(Optional): RS485, Modbus protocol Input: DC 24V(Default), DC 12V(Optioanl) built-in lightning protection Working temperature: -20°C~+60°C Protection level: IP65 Note If you have any questions, please feel fre...

    • ASIN: B07J2HDGDM
    • Brand: Hanchen
    • ASIN: B07J2HDGDM
    • Part No: MX-87a

  • Ultrasonic Level Gauge, Multi Function Indoor Water Tank Liquid Depth Level Meter Sensor with Temperature Indicator Transmitter LCD Digital Display

    Description: Keep an eye on your outdoor water tank from the comfort of your own living room, up to 100m away. Installed at the top of your water tank, the transmitter unit measures the water level using an ultrasonic sensor and temperature using a thermo sensor. You can hang the receiver unit on a wall or pull out the stand and place it on your kitchen bench top, table or desk. View your room's temperature, tank temperature and water level (represented by a 10 element bar graph). You can store min/max records and set alarms for specific water levels (high/low) or when empty. Specification: Indoor Temperature Range: 0~60℃ Outdoor Temperature Range: -40~60℃ Temperature Accuracy: ±1oC Water Level Measure Rang: 0~15m             Resolution: 0.01m             Accurate: +/-0.03M Transmission Frequency: 433MHZ Transmission Range: 100 meters(300 feet)in open area Transmission Interval: 30s when level changes or 3 minutes when level does not change Receiver Battery: 2X AA 1.5V LR3 Alkaline batteries (Not included) Transmitter Battery: 6X AAA 1.5V LR6 Alkaline or lithium batteries (Not included) Battery Life: Minimum 12 months for receiver                   Minimum 12 months for transmitter Receiver Size: 108*9...

    • ASIN: B07N68DFXN
    • Brand: Zerone
    • ASIN: B07N68DFXN
    • UPC: 783335048229
    • Part No: Zerone3ftuhcrpdv

  • Flowline DL14-01 Polycarbonate EchoPod Multi Function Ultrasonic Level Transmitter with Fob, 1" NPT, 4.1' Range

    The general purpose ultrasonic level transmitter provides continuous level measurement up to 49.2" (1.25m) with a 4-20 mA signal output, and is configured via our free Webcal software. The embedded level controller can lower cost by replacing external control hardware. This non-contact liquid level sensor is ideally suited for corrosive, sticky or dirty liquids, and is widely selected for small day tank, skid, IBC, sump and process tank level applications. Range: 49.2" (1.25m). Accuracy: 0.125" (3mm). Resolution: 0.019" (0.5mm). Dead band: 2" (5cm). Beam width: 2" (5cm). Configuration: WebCal PC Windows USB 2.0. Memory: Non-volatile. Supply voltage: 24 VDC (loop). Consumption: 0.5W. Loop resist.: 400O maximum. Signal output: 4-20 mA, two-wire. Signal invert: 4-20 mA or 20-4 mA. Signal fail-safe: 4 mA, 20 mA, 21 mA,22 mA or hold last. Contact type: (4) SPST relays. Contact rating: 60 VA, 1A maximum. Contact fail-safe: Power loss: Hold last. Power on: Open, close or hold last. Hysteresis: Selectable. Process temperature: F: 20 to 140 degree C: -7 to 60 degreee. Temperature comp.: Automatic. Ambient temperature: F: -31 to 140 degree C: -35 to 60 degree .Pressure: MWP = 30 PSI (2 bar). Enclosure rating: Type 6P, encapsulated,corrosion resistant and submersible. Enclosure material: Po...

    • ASIN: B0061OXL1E
    • Brand: Flowline
    • ASIN: B0061OXL1E
    • Part No: DL14-01

  • Flowline LU20-5001-IS EchoTouch IS Ultrasonic Level Transmitter with 18' Cable, 2" NPT

    CSA approved intrinsically safe for use in hazardous locations, the two-wire ultrasonic transmitter provides non-contact level measurement up to 18', and is ideally suited for challenging corrosive, slurry or waste liquids. Push button calibrated, the transmitter is typically selected for atmospheric bulk storage, day tank and waste sump applications located within a classified area. Media examples include diesel fuel and sulfuric acid. The transmitter is calibrated in less than a minute using the LCD display, 4-button interface and intuitive calibration menu. All user set points are held in nonvolatile memory. In the event of acoustic signal loss, the transmitter will hold the current output at the user designated safe state. Range: 6" to 18'. Accuracy: +/- 0.25 percent span in water. Resolution: 0.125". Dead band: 6". Beam width: 8 degree conical. Configuration: push button. Memory: Non-volatile. Display type: LCD, 4-digit. Display units: Inch or cm. Supply voltage: 12 to 32 VDC. Loop resistance: 600 Ohms at 24 VDC. Signal output: 4-20 milliampere, two-wire. Signal invert: 4-20, 20-4 milliampere. Signal fail-safe: reverts to safe state during echo loss. Process temprature: -4 to 140 degreeF. Temprature compensation automatic. Ambient temprature: -40 to 140 degree. Pressure: 30 ...

    • ASIN: B0061OZJ96
    • Brand: Flowline
    • ASIN: B0061OZJ96
    • Part No: LU20-5001-IS

  • Flowline LU81-5101 EchoSpan Ultrasonic Level Transmitter with 18' Cable, 2" NPT

    The general purpose ultrasonic level transmitter provides continuous level measurement up to 32.8' with a 4-20 milliampere signal output, and is configured via its integral push button display module. This non-contact liquid level sensor is ideally suited for corrosive, ultrapure, sticky or dirty liquids, and is broadly selected for bulk storage, day tank, lift station and process tank level applications. Automatic temperature compensation for accurate measurement. Configuration is fast and simple with the scrolling single layer menu, 3-button interface and 6-segment LCD display. Troubleshooting is easy with our powerful setup and diagnostic modes. Setup displays the transmitter’s calibration set points and diagnostics provides users with a snapshot of the installed sensor performance in the application. Range: 8" to 16.4'. Accuracy: +/- 0.2 percent of range. Resolution: 0.039". Dead band: 8". Beam width: 3". Configuration: push button. Memory: non-volatile. Display type: LCD, 6-digit. Display units: Inch, cm and percent. Supply voltage: 12-28 VDC. Loop resistance: 500 Ohms at 24 VDC. Signal output: 4-20 milliampere, two-wire. Signal invert: 4-20, 20-4 milliampere. Signal fail-safe: 4, 20, 21, 22 milliampere or hold last. Process temprature: -7 to 140 degreeF. Temprature compen...

    • ASIN: B0061P0L02
    • Brand: Flowline
    • ASIN: B0061P0L02
    • Part No: LU81-5101

  • Flowline DL34-01 Polycarbonate EchoPod Multi Function Ultrasonic Level Transmitter with Fob, 1" NPT, 18' Range

    The general purpose ultrasonic level transmitter provides continuous level measurement up to 18.0’ (5.5m) with a 4-20 mA signal output, and is configured via our free Webcal software. The level sensor has 4 programmable relays with selectable hysteresis and fail-safe logic. The embedded level controller can lower cost by replacing external control hardware. This non-contact liquid level sensor is ideally suited for corrosive, sticky or dirty liquids, and is widely selected for day tank, skid, IBC, sump and process tank level applications. Range: 18.0' (5.5m). Accuracy: +/- 0.2 percent of range. Resolution: 0.079" (2mm). Dead band: 8" (20cm). Beam width: 3" (7.6cm). Configuration: WebCal PC Windows USB 2.0. Memory: Non-volatile. Supply voltage: 24 VDC (loop). Consumption: 0.5W. Loop resistance: 400O maximum. Signal output: 4-20 mA, two-wire. Signal invert: 4-20 mA or 20-4 mA. Signal fail-safe: 4 mA, 20 mA, 21 mA,22 mA or hold last. Contact type: (4) SPST relays. Contact rating: 60 VA, 1A maximum. Contact fail-safe: Power loss: Hold last: Echo loss: Open, closeor hold last. Hysteresis: Selectable. Process temperature: F: 20 to 140 degree, C: -7 to 60 degree. Temperature comp: Automatic. Ambient temperature: -31 to 140 degree F, -35 to 60 degree C. Pressure: MWP = 30 PSI (2 bar). ...

    • ASIN: B0061OXPVU
    • Brand: Flowline
    • ASIN: B0061OXPVU
    • Part No: DL34-01

  • Flowline LU28-01 EchoSonic II Ultrasonic Level Transmitter with 26.2' Cable and Fob, 2" NPT

    Offered in a type 6P enclosure with cable interface, the general purpose ultrasonic level transmitter provides continuous level measurement up to 32.8' with a 4-20 milliampere signal output, and is configured via our free Webcal software. This non-contact liquid level sensor is ideally suited for corrosive, ultrapure, sticky or dirty liquids, and is broadly selected for bulk storage, day tank, lift station and process tank level applications. Submersible type 6P enclosure is ideal for sump and below grade installations. Short 4" or 8" dead band maximizes the measurable filling capacity of the tank. Measurement range: 8" to 26.2'. Accuracy: +/- 0.2 percent of range. Resolution: 0.079". Dead band: 8". Beam width: 3". Configuration: WebCal PC. Windows USB 2.0. Memory: Non-volatile. Supply voltage: 24 VDC (loop). Consumption: 0.5W. Loop resistance: 500 ohms at 24 VDC. Signal output: 4-20 milliampere two-wire. Signal invert: 4-20 or 20-4 milliampere. Signal fail-safe: 4, 20, 21, 22 milliampere or hold last. Process temprature: -4 degree to 140 degree F. Temprature compensation: automatic. Ambient temprature: -31 degree to 140 degree F. Pressure: MWP equal to 30 PSI. Enclosure rating: Type 6P, encapsulated, corrosion resistant and submersible. Enclosure material: polycarbonate. Transdu...

    • ASIN: B0061OZXCY
    • Brand: Flowline
    • ASIN: B0061OZXCY
    • Part No: LU28-01